Description (partial)

Symptom:
On Nexus 7000 when performing EPLD verification with recent version of EPLD then NX-OS software it will fail with error of not enough space:

NX-OS Version 6.1(4)

show version epld bootflash://sup-1/n7000-s2-epld.6.2.2.img 

Retrieving EPLD versions... Please wait.

Could not extract EPLD images, Insufficient space in bootflash.
Failed to extract EPLD image versions, Exiting..

Conditions:
Perform EPLD version check for subsequent EPLD version, for ex. if NX-OS 6.1(4) used and EPLD version checked is for 6.2(2):

show version epld bootflash://n7000-s2-epld.6.2.2.img 