Cisco Bug: CSCua96291 - ASR903:Interface goes down with no neg auto on one side post sh/no sh

Last Modified

Jan 30, 2017

Products (1)

  • Cisco ASR 900 Series Aggregation Services Routers

Known Affected Releases

15.3(1)S

Description (partial)

Symptom:
on A900-IMA8S,if one end is autoneg enabled and other end is autoneg disabled, link stays down on the end with autoneg enabled.
on A900-IMA8T, when speed is forced to 1000mbps on one of the interfaces, link goes down after performing a sh/no sh
Conditions:
on A900-IMA8S, mismatch of autoneg on the connected interfaces
on A900-IMA8T,performing sh/no sh after forcing speed to 1000mbps