Guest

Preview Tool

Cisco Bug: CSCte74879 - WLC5508 agentSwitchInfoPowerSupply MIB does not work

Last Modified

Jun 30, 2016

Products (1)

  • Cisco 5500 Series Wireless Controllers

Known Affected Releases

6.0(188.0)

Description (partial)

Symptom:
====================
WLC5508 agentSwitchInfoPowerSupply MIBs are always same value 
regardless of the real power unit status.

http://tools.cisco.com/Support/SNMP/do/BrowseOID.do?objectInput=agentSwitchInfoPowerSupply1Present&translate=Translate&submitValue=SUBMIT
 agentSwitchInfoPowerSupply1Present     : true(1)
 agentSwitchInfoPowerSupply1Operational : true(1)
 agentSwitchInfoPowerSupply2Present     : false(0)
 agentSwitchInfoPowerSupply2Operational : false(0)

Power supply unit is inserted to slot 2, then power on, but the agentSwitchInfoPowerSupply2Present and agentSwitchInfoPowerSupply2Operational are still false(0).
Power supply unit is removed from slot 1, but the agentSwitchInfoPowerSupply1Present and agentSwitchInfoPowerSupply1Operational are still true(1).


Condition:
===========
 Reproducibility : Yes

Components:
===========
  Software: 6.0.188.0
  Hardware: WLC5508
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.