Cisco Bug: CSCtc35420 - SMR: circuit far from pwr target after OOS->IS if Forced = ON

Last Modified

Feb 19, 2010

Products (1)

  • Cisco ONS 15454 Series Multiservice Provisioning Platforms

Known Affected Releases

9.10

Description (partial)

Symptom:
Target power not reached on Line-TX. 

Conditions:
Have a circuit active on a SMR-2 based node.
On the SMR-2 force to ON the OCH on LINE-TX.
Then disable the circuit and then reactivate it.
The circuit is reactivated, but the target power on the LINE-TX is not met.
Circuit is sent out at -18dBm intstead of the expected 2dBm.