Cisco Bug: CSCtc00828 - varbind value of cefcFRUPowerOperationStatus shows incorrect temp value

Last Modified

Feb 22, 2014

Products (3)

  • Cisco Nexus 5000 Series Switches
  • Cisco Nexus 5020 Switch
  • Cisco Nexus 5010 Switch

Known Affected Releases

4.0(1a)N2(1a) 4.1(3)

Description (partial)

Symptom:

The varbind value received in the cefcFRUPowerOperationStatus in the cefcPowerStatusChange snmp trap shows wrong value


Conditions:

When the air entry is blocked  on the power supply, a console message is seen after 10 minutes
%NOHMS-2-NOHMS_DIAG_ERR_PS_FAIL: System minor alarm on power supply 2: failed
The snmp trap generated to the management station shows value of 1 (offEnvOther) instead of  value 6 (offfEnvTemp)
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.