Cisco Bug: CSCtb94487 - "Heartbeat missed" message seen on Trex after g_spa_0 process restart

Last Modified

Jan 13, 2017

Products (1)

  • Cisco 12000 Series Routers

Known Affected Releases

3.8.2.BASE

Description (partial)

Symptom:
For a Trex SPA, the following console logs and trace backs appear in the router:
PLIM_HEARTBEAT_ERR : SPA-1XCHOC48/DS3: bay 0 heartbeat missed, expected seq# 0 received seq# 7797, Time since last message 103s 
g_spa_0[154]: %L2-CEMA-4-GEN_ERR : CEMA Internal Error: NULL DSX1 plugin  :

Conditions:
Router running r3.8.2 image.
Process restart of g_spa for the trex spa.