Guest

Preview Tool

Cisco Bug: CSCtb61696 - EW EnergyWise Device level task will fail for device with IPV6 address

Last Modified

Jul 11, 2010

Products (1)

  • CiscoWorks Resource Manager Essentials

Known Affected Releases

4.3(1)

Description (partial)

Symptom:

An error message is thrown while configuring EnergyWise on the device with IPv6 Address.

Conditions:
This occurs when you:
1. Manage a device with IPv6 address in DCR.
2. Perform config fetch for the device in RME.
3. Create a Netconfig device based job by selecting Energywise task.
4. Select Use Mgmt IP Address of Devices option in the EnergyWise Configuration task page.
5. Save the EnergyWise Configuration.
6. Click View CLI to view the generated command. 
For example, the command should be in the following format:
      energywise domain dsf secret *** protocol udp port 43440 ip 2001:0DB8:0:ABCD::1 
In this case, configuring the command on the device throws the following error message:

4507E-Mara(config)#$domain dsf secret cisco protocol udp port 43440 ip 2001:41$
energywise domain dsf secret cisco protocol udp port 43440 ip 2001:0DB8:0:ABCD::1                                     					       ^
% Invalid input detected at '^' marker.
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.