Description (partial)

Symptom:
The N1K has 16 VEMs connected, each ESX/VEM two pNIC and host a few virtual machines. Each virtual machine has two vNIC, both connected to the N1K.

When a few virtual machines are power on or off together from the vCenter, most of the time, there will be one or more VEM disconnect from the VSM randomly. The VEM disconnect because of heartbeats lost:
2009 Aug 19 22:03:06.228 n1kv-eng %PLATFORM-2-PFM_VEM_REMOVE_NO_HB: Removing VEM 12 (heartbeats lost)
2009 Aug 19 22:03:06.255 n1kv-eng %PLATFORM-2-MOD_REMOVE: Module 12 removed (Serial number )
2009 Aug 19 22:03:06.282 n1kv-eng %VIM-5-IF_DETACHED_MODULE_REMOVED: Interface Ethernet12/3 is detached (module removed)
2009 Aug 19 22:03:06.282 n1kv-eng %VIM-5-IF_DETACHED_MODULE_REMOVED: Interface Ethernet12/4 is detached (module removed)

Conditions:
Powering on/off more than 10 virtual machines at one go.