Description (partial)

None
 Symptom:
 On a PRP3, a process that communicates to the fabric can get into a state 
where the communication 
 channel is not initialized correctly.  This causes no fabric communication 
for that process.
 
 This can happen where qnet does not work, so install package download fails.
 This can happen where netio cannot talk to other netio instances on other 
nodes via the fabric, 
 thus, ping fails.
 This can happen where sysldr fabric ping fails causing nodes and router 
reload.
 This can happen where nsr does not work due to nsr protocols cannot sync up 
between active/standby 
 and other nodes.
 This can happen where gsp does not work, causing gsp and other gsp based 
application to fail.

This problem is specific to PRP3.

Other symptoms:

sh contr fabricq trace errors loc <> gives:

Jul 29 11:14:21.447 prp3fab/clnt01/err 0/0/CPU0 t15 Strm: 4 tfb 
packet_tx_pak: Tx State does NOT allow pkt send. Client(1) Port(3) Tx State: 
ToFab side is disabled. Port CB State: Not servicing FabMsg CBs

sh contr fabricq tofab detail loc <> says TxState as 17 for a fabric port:

 Hummer Information
--------------------
Per Port Rx/Tx Information
---------------------------
Port  RxState  TxState  CbState  FFPktIndx  TxRqIndxTxDnIndx  TxCrdt  
TxDescCnt
 0      2        1         0           44      119      117         1      
510 
 1      2        1         0            0        0        0         0      
512 
 2      2        1         0            0        0        0         0      
512 
 3      5       17         0            0        0        0         1      
512 
 4      2        1         0            0        0        0         0      
512 
 5      0        1         0            0      160      159         1      
511 
 6      2        1         0            0        0        0         0      
512 
 7      2        1         0            0        0        0         0      
512 
12      2        1         0            0        0        0         0      
512 
13      2        1         0            0        0        0         0      
512 
14      2        1         0            0        0        0         0      
512 
15      2        1         0            0        0        0         0      
512 



 Conditions:
 
 When the fabric ASIC on the PRP3 is first initialized, or re-initialized due 
to error conditions, 
 or CSC switchover, then the fabric process owning the fabric ports may not 
able to re-initialize 
 the fabric ports due to it being in a deadlock state.
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.