Description (partial)

Symptom:
 40MUX-C optical card with VID 1025 is not reporting the value of the optical
power in the Provisioning/Optical Channel pane  when a OCH-ckt is not created
on the card . 
 
 A consequence of the above problem is that the Raman Installation Wizard 
fails in tuning the RAMAN span when MUX/DEMUX option is selected and a 40MUX-C
 (VID 1025 ) is used
 
 
 Conditions:
 The problem occurs when an optical signal is injected into any of the CHAN-RX
add ports and the COM-TX port is in IS-AINS status. This bug is only really a
problem when using the Raman wizard.