Symptom:

After replacing a faulty fan tray on a Nexus 7000, the failed status is not cleared, and the diagnostics continue to report the failure.

Example:

%DEVICE_TEST-2-FAN_MOD_FAIL: Module 5 has failed test SystemMgmtBus 20 times on System Mgmt Bus for chassis FAN instance 2 due to error Device fan is found to be bad error number 0x00000002

%MODULE-4-MOD_WARNING: Module 5 (serial: XXX123YYYY) reported warning due to Device fan is found to be bad in device 0 (device error 0x2)


Conditions:
This can occur on any Nexus 7000 switch running NX-OS earlier than 4.2(3)


Workaround(s):

None. This is resolved in 4.2(3) and later releases. 