Preview Tool

Cisco Bug: CSCta35560 - Standby XC reboots continuously after an autoreset

Last Modified

Feb 22, 2014

Products (1)

  • Cisco ONS 15454 Series Multiservice Provisioning Platforms

Known Affected Releases


Description (partial)

   Auto/Manual reset of XC card results in continuous reboots of Standby XC 
  It happens only if non-revertive UPSR/SNCP HO/LO circuits are provisioned on 
 that node.
  1) Create multiple non-revertive UPSR/SNCP HO/LO circuits on 15454 /15310MA 
  3) Few/All UPSR/SNCP circuits are in switched state. Traffic is active on 
 the protect path on those circuits.
  2) Delete any intermediate UPSR/SNCP HO/LO circuit. Do not delete last 
 provisioned UPSR/SNCP circuit.
  3) Auto reset/Manual reset of the standby XC/CTX card.
  4) Standby XC/CTX card goes for continuous reset.
  Issue happens on 15310MA node as well on 15454 node too.
  On 15454, It happens only with XCVXC card.
 Issue is present in 6.2 release. It is fixed in 7.0 release.
Bug details contain sensitive information and therefore require a account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.