Guest

Preview Tool

Cisco Bug: CSCsz23225 - no power redundancy-mode ... doesn't revert to default config

Last Modified

Feb 04, 2017

Products (1)

  • Cisco Nexus 7000 Series Switches

Known Affected Releases

4.1(3)

Description (partial)

Symptom:
When issuing the "no power redundancy-mode " command, the expectation is that the system reverts to the default redundancy mode which is "ps-redundant". The system however will revert to "redundant" mode.

Conditions:
When default power redundancy configuration has been changed.

Workaround(s):
Configure "power redundancy-mode ps-redundant" manually instead of "no power redundancy-mode ".

Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.