Preview Tool

Cisco Bug: CSCsy84837 - RDU under load drops connection to 2.6 DPE

Last Modified

Feb 22, 2014

Products (1)

  • Cisco Broadband Access Center for Telco and Wireless

Known Affected Releases

2.6(2.8) 4.0(1.0)

Description (partial)

After a connection between the RDU and the DPE has been up for about two minutes, the RDU drops the connection to the DPE, as indicated by a log message similar to the following:

rdu: 2009 03 27 16:58:48 UTC: %BAC-RDU-3-1159: Closing connection to []. [2] consecutive read timeout(s) occurred. Rate [115/d].

The DPE re-establishes the connection, but the problem repeats.

RDU server is running version 4.0.1 or 2.7.1.
DPE server is running version 2.6.2.
RDU server is experiencing configuration generation load, causing constant communication to the DPE server(s).
The DPE server(s) are not posting batches, no communication is going to the RDU server.