Cisco Bug: CSCsg39687 - multiple fabric planes down after admin reload

Last Modified

Feb 05, 2017

Products (1)

  • Cisco Carrier Routing System

Known Affected Releases

3.3.4.BASE

Description (partial)

Symptom:
After an admin reload loc all, sfe_drvr restarts multiple times on some fabric cards in the system, and the planes corresponding to those cards remain Down. The following error messages are observed on the console:
SP/F1/SM4/SP:Oct  9 17:34:02.780 : sfe_drvr[114]: %FABRIC-FABRIC_DRVR-3-ERR_POD_INIT : Failed to reset POD (node: 0xf1040, module: 0x20000, asic: 1, POD:1) - error : ''sysdb'' detected the ''warning'' condition ''An EDM took too long to process a request and was timed out''; exiting... 
adminSP/F1/SM4/SP:Oct  9 17:34:03.764 : sfe_drvr[114]: Load SEA Driver DLL.

SP/F1/SM4/SP:Oct  9 17:34:02.907 : sysmgr[75]: sfe_drvr(1) (jid 114) abnormally terminated, restart scheduled 


Conditions:

This issue was seen during router reload, when initiated with the "admin reload location all" command.